Lesson: IMRT Module
IMRT Treatment Planning

Next we will evaluate the rest of the original treatment plan directives;
We have already confirmed the dose, and the 95% coverage.
Plan Directives; Dose: 50 GY (2Gy X 25fx) 
95% of PTV Receives 100% of Rx 
Nothing receives > 110% of Rx dose (if possible)
Spinal Cord: .1cc < 25GY
Rt Kidney: Max Point Dose < 18 Gy
Lt Kidney: Max Point Dose < 18 Gy
Lungs: V5 < 50%
V20 < 15%
 |
Page 17 of 24 |
 |